PCI2000PFB

overview
Click on image to get the full sizeapplicomR , based on our open industrial communication concept , is designed for applications such as SCADA, MES, RDBM, spreadsheets, specific developments, etc., which require communication with devices connected on fieldbuses or industrial networks. The applicomR package includes software and smart board(s) specific for each type of fieldbus or industrial network. Thanks to its smart technology, all applicomR boards are able to execute the management and the treatment (polling, frame management, etc.) of the embedded protocols, resulting in remarkable application performance.

Particularly, the applicomR PCI2000PFB board is equipped  with 1 Profibus port and 1 serial port, respectively managing Profibus DP Master protocol and all supported serial protocols
.

applicom international is a member of PTO (Profibus Trade Organization) and PNO (Profibus Nutzerorganisation e.V.).


paltforms

Compatible Platforms

Windows 2000 / XP

Windows NT 4.0 - Intel

Windows 95, 98



protocols

Compatible Profibus Protocols

Devices

DP Master Class-1, Class-2

All DP slave devices

Serial Protocols

Devices

3964/3964R (free messaging or RK512)

SIEMENS Simatic S5

AS511

SIEMENS Simatic S5 (programming port)

Batibus

Merlin Gerin (building automation)

Data Link

Elsag Bailey

DF1, DH, DH+, DH-485 *

Rockwell Automation (programming port)

Modbus (master & slave)

All Modbus & Jbus devices

PPI+, PPI

SIEMENS Simatic S7-200 (programming port)

Saïa Bus

Sa?/FONT>a

SNP-X

GE-Fanuc/Cegelec

SucomA

Kl?/FONT>ckner-Moeller

Sysmac Way

Omron

TI-Dir

SIEMENS Simatic TI-505 (programming port)

Uni-Telway (master & slave)

Groupe Schneider

Kit4000TD

Development toolkit for serial protocols

* DF1: for DH and DH+ via 1770-KF2.  For DH-485 via 1770-KF3 (1770-KF2 and 1770-KF3 not included)



technical data

Technical Data

 

Unit

PCI PC board

Processor

Intel 80386EX - 32 MHz

Memory

4 Mbytes dynamic RAM

Flash memory

512 Kbytes flash memory

Supported Interrupts

Hardware Plug&Play

DPRAM Address

Hardware Plug&Play (32 Kbytes used per board)

Discrete Input*

Opto-coupled discrete input
Voltage -> DC +10 to +30 or AC 24 V
(50 to 60 Hz)

Discrete Output*

"WatchDog" output contact free from potential (floating) (24V DC, 0.25 A)

Technology

SMC technology; Complies with EMC for both Industrial and office use

Dimensions (L x W)

175mm x 107mm (6.89" x 4.21")

Consumption

4 W (max. 0.8A)

Operating Temperature

0?C (32?F) up to +65?C (149?F)

Storage Temperature

-40?C (-92?F) up to +80?C (176?F)

(*) The discrete I/O´s are mounted on a special bracket (ref: IOSPKIT), and require an additional rear panel slot.

Profibus Port

 

Interface type

1 Profibus port (EN 50 170)

Connector Type

9-pin Sub-D female

Speed

9600 Kbps to 12 Mbps

Transmission LEDs

1 Transmit LED / 1 Receive LED

Electrical interface

RS485 with galvanic insulation (500 volts)

Serial Port

 

Port Type

1 asynchronous serial port

Connector Type

9-pin Sub-D male

Transmission LEDs

1 Transmit LED / 1 Receive LED

Electrical Interface

Plugged on board:

  • RS232C (2 or 6 signals) interface
  • RS232C (2 or 6 signals) interface with galvanic insulation (500 Volts)
  • RS485/RS422 interface
  • RS485/RS422 interface with galvanic insulation (500 Volts)
  • 20mA current loop interface
  • Batibus interface

Baud Rate

from 50 to 38400 bps

Supported Format

  • 7 or 8 data bits
  • 1 or 2 stop bits
  • odd, even or no parity


utilities

Utilities

Board configuration utility (devices, protocols, communication parameters)

Cyclic function configuration utility

Diagnostics and test programs


PROFIBUS-DP Diagnostic tool



add-on

Connectors

Profibus connector (Siemens)

Brackets

Discrete I/O´s and serial port bracket

Electrical Interfaces

RS232C

RS232C with galvanic insulation

RS422/RS485

RS422/RS485 with galvanic insulation

20mA current loop

Profibus module

Profibus module with galvanic insulation

Batibus module



ordering

applicom® on PCI2000PFB board

Reference

under Windows NT Intel, Windows 2000 / XP

PCI2000PFB/NT

under Windows 95/98

PCI2000PFB/W95

Bracket

Reference

Discrete I/O´s and serial port bracket

IOSPKIT

Connector

Reference

Bus connector (Siemens)

6GK1 500 0EA00

Electrical interfaces

Reference

RS232C

5RS232

RS232C with galvanic insulation (500 volts)

6RS232

RS422/RS485

5RS485

RS422/RS485 with galvanic insulation (500 Volts)

6RS485

20mA current loop

5BC20

Profibus module

5PFB485

Profibus module with galvanic insulation

6PFB485

Batibus module

5BCBAT

Profibus Protocol

Devices

Reference

DP Master

All DP slave devices

PC/PFB

Serial Protocols

Devices

Reference

3964/3964R

SIEMENS Simatic S5

PC/39

AS511

SIEMENS Simatic S5 (programming port)

PC/AS

Batibus

Merlin Gerin (building automation)

PC/BAT

Data Link

Elsag Bailey

PC/DA

DF1, DH, DH+, DH-485*

Rockwell Automation (programming port)

PC/DF

Modbus

All Jbus or Modbus devices

PC/MB

PPI+, PPI

SIEMENS Simatic S7-200 (programming port)

PC/PPI

Sa?/FONT> a Bus

Sa?/FONT>a

PC/SB

SNP-X

GE-Fanuc/Cegelec

PC/SNP

SucomA

Kl?/FONT>ckner-Moeller

PC/SU

Sysmac Way

Omron

PC/SW

TI-Dir

SIEMENS Simatic TI-505 (programming port)

PC/TI

Uni-Telway

Groupe Schneider

PC/TE

Kit4000TD

Development toolkit for serial protocols

KIT4000TD